FIXED GAS DETECTOR - DETECTOR HEAD

GAS DETECTOR HEAD D58 SERIES

SPECIFICATION

Target gas : Combustible

Explosion proof : Flameproof enclosure

Approvals : ATEX, CE, TIIS

Dimensions & WeightApprox. : 197 (W) x 286 (H) x 140 (D) mm, Approx. 5.8kg

GAS DETECTOR HEAD GD-K88 SERIES

FEATURE

2-wire system gas detector
Built-in aspirator(Optional)
Corrosive gas protection structure
Intrinsically safety (By using as exclusive zener barrier)

SPECIFICATION

Target gas : Toxic

Detection principle : Electrochemical

Explosion proof : Intrinsically safe (with zener barrier)

Approvals : TIIS

GAS DETECTIR HEAD GD-A80 SERIES

APPLICATION

Gas leak monitoring to prevent explosive accident in hazardous areas of various industories.

FEATURE

Ex-proof design
Covering wide detection range from ppm to %LEL
Long life sensor

SPECIFICATION

Target gas : Combustible, Toxic

Sampling method : Diffusion

Explosion proof : Flameproof enclosure

Approvals : ATEX, IECEx, CE, TIIS

Dimensions & Weight : Approx. 78 (W) x 154 (H) x 105 (D) mm, Approx. 1.0kg

GAS DETECTOR HEAD INSIDE FURNACE GD-A2400

APPLICATION

Detector for high-boiling solvent in exhaust duct and furnace

FEATURE

Long sensor head (250mm in length)
Operating in high temp. 0 to 160℃
Flameproof enclosure
Easy operation with control key

SPECIFICATION

Target gas : NMP (N-methylpyrrodidone)

Detection principle : Catalytic combustion

Sampling method : Diffusion

Explosion proof : Flameproof enclosure

Approvals : ATEX, TIIS, CE

Power source : DC24V

Dimensions & Weight : Main body: 148(W) x 161(H) x 88(D) mm 
                                        Insert part: φ34 x 250 mmApprox 4.6kg

Operating temperature & Humidity : Main body: 0 to 50 ℃ Insert part: 0 to 160℃

GAS DETECTOR HEAD GD-F3A-1

APPLICATION

Oxygen monitoring to prevent oxygen deficiency accident in various industories.

FEATURE

Compact & light weight design
Splash-proof construction
Intrinsically safe with zener barrier

SPECIFICATION

Target gas : Oxygen

Detection principle : Galvanic cell

Sampling method : Diffusion

Explosion proof : Intrinsically safe (with zener barrier)

Approvals : CE, With TIIS (with zener barrier)

Operating temperature & Humidity : -10 to 40℃, Below 90%RH (Non-Condensing)

GAS DETECTOR HEAD GD-F4A-1

APPLICATION

Oxygen monitoring to prevent oxygen deficiency accident in various industories.

FEATURE

Compact & light weight design
Splash-proof construction
Intrinsically safe with zener barrier

SPECIFICATION

Type : Galvanic cell

Target gas : Oxygen

Sampling method : Sample draw (No pump in GD-F4A-1)

Explosion proof : Intrinsically safe (with zener barrier)

Approvals : CE, TIIS (with zener barrier)

Dimensions & Weight : -10 to 40℃, Below 90%RH (Non-Condensing)

Operating temperature & Humidity : Detector head

GAS DETECTOR HEAD GD-F44

APPLICATION

Oxygen monitoring to prevent oxygen deficiency accident in various industories.

FEATURE

Flameproof enclosure

SPECIFICATION

Target gas : Oxygen

Detection principle : Galvanic cell

Sampling method : Diffusion

Explosion proof : Flameproof enclosure

Approvals : CE, TIIS, KOSHA, KIMM, CCS

Operating temperature & Humidity : -10 to 40℃, Below 90%RH (Non-Condensing)

Please reload

RIKEN KEIKI (M) SDN BHD             ​   

66-2 Jalan 27/70A                                     info@rikenkeiki.com.my

Desa Sri Hartamas                                    +603-6206 2880

50480 KUALA LUMPUR,

MALAYSIA

                                                                                                                                             Copyright© 2018 RIKEN KEIKI Malaysia. All Rights Reserved.

  • Facebook Social Icon
  • Twitter Social Icon
  • Google+ Social Icon